xnorit:public:summary:xnorduino
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| xnorit:public:summary:xnorduino [2024/10/13 10:36] – [Power monitoring] timdv91 | xnorit:public:summary:xnorduino [2026/03/08 14:09] (current) – timdv91 | ||
|---|---|---|---|
| Line 58: | Line 58: | ||
| The termination brick power-consumption is extremely low, meaning that our 5V power-rail suffices as it's power source on even longer cable runs. The Bus-master reads an " | The termination brick power-consumption is extremely low, meaning that our 5V power-rail suffices as it's power source on even longer cable runs. The Bus-master reads an " | ||
| - | This feature was implemented, | + | This feature was implemented, |
| - | Additionally, | + | Additionally, |
| \\ | \\ | ||
| Line 69: | Line 69: | ||
| {{ : | {{ : | ||
| - | Our 24V power-rail has a maximum current that depends on the utilized cat-cable. I therefore implemented a digital current-sense IC on the master, which disables the 24V power-rail pro-grammatically whenever our current draw surpasses a certain pre-configured value. For safety reasons, any over-current detection disables the 24V rail permanently, | + | Our 24V power-rail has a maximum current that depends on the utilized cat-cable. I therefore implemented a digital current-sense IC on the master, which disables the 24V power-rail pro-grammatically whenever our current draw surpasses a certain pre-configured value. For safety reasons, any over-current detection disables the 24V rail permanently, |
| Additionally the power-monitor IC reads the 24V rail voltage at the beginning of the communication bus. The Termination-brick measures the 24V rail at the end of the bus, meaning we can calculate the voltage drop across our bus by subtracting these two. | Additionally the power-monitor IC reads the 24V rail voltage at the beginning of the communication bus. The Termination-brick measures the 24V rail at the end of the bus, meaning we can calculate the voltage drop across our bus by subtracting these two. | ||
| + | \\ | ||
| \\ | \\ | ||
| \\ | \\ | ||
| Line 83: | Line 84: | ||
| Below are some (approved) example images of various slave devices. | Below are some (approved) example images of various slave devices. | ||
| + | * PWM Fan controller | ||
| + | * Current and voltage sense | ||
| + | * 16 bit ADC modules | ||
| + | * Humidity and temperature module | ||
| + | * Weather station module | ||
| + | * LED driver modules | ||
| + | * etc ... | ||
| {{: | {{: | ||
xnorit/public/summary/xnorduino.1728815768.txt.gz · Last modified: by timdv91