Line 58: Line 58:
 The termination brick power-consumption is extremely low, meaning that our 5V power-rail suffices as it's power source on even longer cable runs. The Bus-master reads an "heartbeat" from this termination brick in a 20 ms interval. The 24V power-rail gets enabled, whenever the termination brick is successfully detected by the master. The master disables the 24V power-rail within 50 ms, whenever the termination-brick gets disconnected. This feature functions fully automatically, without any human intervention.   The termination brick power-consumption is extremely low, meaning that our 5V power-rail suffices as it's power source on even longer cable runs. The Bus-master reads an "heartbeat" from this termination brick in a 20 ms interval. The 24V power-rail gets enabled, whenever the termination brick is successfully detected by the master. The master disables the 24V power-rail within 50 ms, whenever the termination-brick gets disconnected. This feature functions fully automatically, without any human intervention.  
  
-This feature was implemented, to prevent accidentally inserting 24V on standardized network equipment. Which could potentially cause damage on certain devices.+This feature was implemented, to prevent accidentally inserting 24V on standardized network equipment. Which could potentially cause damage on certain devices. A red LED starts to blink on the master, whenever the termination module gets disconnected. 
  
-Additionally, the termination brick measures temperature and the voltages of both power rails (as can be seen in the image underneath). +Additionally, the termination brick measures temperature and the voltages of both power rails (as can be seen in the right image). A red LED starts to blink on the master, whenever the voltage drop across master and termination modules become to large. 
  
 \\ \\
Line 84: Line 84:
  
 Below are some (approved) example images of various slave devices. Below are some (approved) example images of various slave devices.
 +  * PWM Fan controller
 +  * Current and voltage sense
 +  * 16 bit ADC modules
 +  * Humidity and temperature module
 +  * Weather station module
 +  * LED driver modules
 +  * etc ...
  
 {{:xnorit:public:summary:xnorduino:img-20210903-wa0003.jpg?400|}} {{:xnorit:public:summary:xnorduino:img-20210903-wa0003.jpg?400|}}