User Tools

Site Tools


xnorit:public:summary:xnorduino

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
xnorit:public:summary:xnorduino [2024/10/13 10:41] – [Bus-Slaves] timdv91xnorit:public:summary:xnorduino [2026/03/08 14:09] (current) – timdv91
Line 58: Line 58:
 The termination brick power-consumption is extremely low, meaning that our 5V power-rail suffices as it's power source on even longer cable runs. The Bus-master reads an "heartbeat" from this termination brick in a 20 ms interval. The 24V power-rail gets enabled, whenever the termination brick is successfully detected by the master. The master disables the 24V power-rail within 50 ms, whenever the termination-brick gets disconnected. This feature functions fully automatically, without any human intervention.   The termination brick power-consumption is extremely low, meaning that our 5V power-rail suffices as it's power source on even longer cable runs. The Bus-master reads an "heartbeat" from this termination brick in a 20 ms interval. The 24V power-rail gets enabled, whenever the termination brick is successfully detected by the master. The master disables the 24V power-rail within 50 ms, whenever the termination-brick gets disconnected. This feature functions fully automatically, without any human intervention.  
  
-This feature was implemented, to prevent accidentally inserting 24V on standardized network equipment. Which could potentially cause damage on certain devices.+This feature was implemented, to prevent accidentally inserting 24V on standardized network equipment. Which could potentially cause damage on certain devices. A red LED starts to blink on the master, whenever the termination module gets disconnected. 
  
-Additionally, the termination brick measures temperature and the voltages of both power rails (as can be seen in the image underneath). +Additionally, the termination brick measures temperature and the voltages of both power rails (as can be seen in the right image). A red LED starts to blink on the master, whenever the voltage drop across master and termination modules become to large. 
  
 \\ \\
xnorit/public/summary/xnorduino.1728816096.txt.gz · Last modified: by timdv91